AAMA 501.2-03 PDF

A M E R I C A N A R C H I T E C T U R A L AAMA Quality Assurance and Diagnostic Water Leakage Field Check of Installed. AAMA Test Method Field testing by an AAMA Accredited 3rd Party Test Agent. Enclosure Commissioning a crash course in reality -?? Water ASTM E, D, AAMA Air ASTM E , E, E Adhesion.

Author: Dozshura Kazigrel
Country: Sao Tome and Principe
Language: English (Spanish)
Genre: Technology
Published (Last): 5 May 2007
Pages: 35
PDF File Size: 3.75 Mb
ePub File Size: 9.48 Mb
ISBN: 132-2-80728-658-2
Downloads: 10613
Price: Free* [*Free Regsitration Required]
Uploader: Mikakazahn

AAMA is the proper test method for field testing of storefronts, curtain walls, and slope glazing for air leakage resistance and water penetration resistance performance. The procedure outlined in this document is not intended to test the rated or specified water performance representative of a wind driven rain event.

This field check method is not appropriate for testing of operable components such as operable windows and doors. The area to be tested shall include, perimeter caulking, typical splices, frame intersections, and, if applicable, at least 2 entire vision lites and 2 entire spandrel lites containing an intermediate vertical member and an intermediate horizontal member.

The Red document status indicator indicates that the document is an old version The document has likely been withdrawn by the publisher, also the meta data presented here may be out of date as it is no longer being maintained by the editorial teams at NBS. Begin your publication search by entering information into the fields below.

To pinpoint the weak spots in construction, a waterproof tape can be used to completely seal the area. Professional services based on accurate information that helps you or your company make the right decision regarding your project or asset. We provide testing services throughout the United States from our headquarters located in Atlanta, GA.

  EBOOK RAHASIA GOOGLE ADSENSE FILETYPE PDF

Building Diagnostics Group, Inc. Failures during quality assurance new construction testing can result in unnecessary delays that can impact your bottom line. Please read our simple purchasing instructions first to ensure a smooth transaction.

aama-501.2-03-fieldcheckwater-hosetest.pdf

American Architectural Manufacturers Association The American Architectural Manufacturers Association produces performance standards, product certification and educational programs for the fenestration industry.

Water contained within drained flashings, gutters, and aqma is not considered water leakage. Free to use BIM project management tool provides step-by-step help to define, manage and validate responsibility for information development and delivery at each stage of the asset life cycle in level 2 BIM projects. Want access to British Standards?

The chosen area is soaked from the lowest horizontal brace to any adjacent vertical framing. The test area shall be a representative sample of typical construction and shall have no outstanding punch list items or other visible defects. Remedial work involving the use of curing-type compounds shall be allowed to set before it is re-checked for leakage. 501.2-03 purpose of this specification is to provide axma quality assurance and diagnostic field water check method for installed storefronts, curtain walls and sloped glazing systems.

This document Newer versions. The requirement of AAMA accreditation assures the specifier that the laboratory has the staff, training, experience, and calibrated equipment to properly perform field testing.

All of this work shall be done in strict accord with approved shop drawings and job specifications. The values given in parentheses are for reference only. For the actual test, a 501.2-30 section is chosen that bears both the frame and a joint in the glass. Search by product code or category or leave the product code field blank to see a list of all AAMA publications.

Also state whether or not the results indicate compliance with the field testing specification requirements for the project.

  KYRA KYRALINA PDF

All aamaa, gaskets, and framing elements are covered from the outside and removed in 5-foot sections to retest for the exact spot of leakage. The American Architectural Manufacturers Association produces performance standards, product certification and educational programs for the fenestration industry.

AAMA Pubstore Product Listings –

Manufacturer, model, dimensions, materials, etc. During the test, an observer on the indoor side of the wall, using a flashlight if necessary, shall check for any water leakage and shall note where it occurs.

This allows us to not only properly test fenestrations on new construction projects, but also pinpoint the cause of any test failures and provide accurate recommendations to achieve successful testing results.

If no leaks occur, the area stays uncovered, and the test goes on. Again there may be more recent versions of the document.

The AAMA 501.2 Kit

AAMA is sama proper test method for field air leakage resistance and water penetration resistance testing of operable windows and doors. Testing shall wama performed as soon as possible after the fenestration product is installed and prior to the installation of drywall or other interior finish wall materials. For this water leakage field check, water leakage is defined as any uncontrolled water that appears on any normally exposed interior surfaces, that is not contained or drained back to the exterior, or that can cause damage AAMA Document Status Indicators The Green document status indicator indicates that the document is: