CIERRE DE COMUNICACION INTERAURICULAR PDF

Request PDF on ResearchGate | Cierre de la comunicación interauricular con dispositivo oclusor implantado mediante cateterismo cardíaco | Since King and. PDF | La comunicación interauricular (CIA) es uno de los defectos congénitos que se Cierre de comunicacion interauricular por cateterismo. Presentamos nuestra experiencia inicial en cierre de la comunicación interauricular (CIA) por vía derecha, comparándola con esternotomía media. Entre julio.

Author: Menos Dibei
Country: Albania
Language: English (Spanish)
Genre: Life
Published (Last): 4 September 2013
Pages: 59
PDF File Size: 6.52 Mb
ePub File Size: 13.91 Mb
ISBN: 126-1-59548-842-4
Downloads: 7265
Price: Free* [*Free Regsitration Required]
Uploader: Tom

Follow up should include transthoracic echocardiography TTE the day following device deployment. In summary, the baseline TEE comuunicacion meet the criteria described in Table 2 in order for the patient to be eligible for percutaneous closure.

Afterwards, it is re-infated to the SBD volume and measured against a sizing plate.

Comunicación interauricular

Transesophageal echocardiography multimedia manual: The ideal scenario for PTC is a single ASD with a maximal diameter of less than 20 mm, 8 with firm and adequately sized rims. A major concern in the presence of two separate septal defects Figure 10 is the possibility of missing other supplementary defects.

Frequency of atrial septal aneurysms in patients with cerebral ischemic events. When a large Eustachian valve EV or Chiari network is present, it should be mentioned to the operator because it can cause device entrapment during deployment of the right atrial disk.

Immediate post procedural evaluation A thorough evaluation onterauricular presence of residual shunts is performed for future correlation. The mid-esophageal bi-caval view provides an excellent view of the inter-atrial septum, allowing interrogation of the septum with CD.

Several authors have referred to these edges with anatomical connotations and others with spatial connotations. Nearby structures might be compromised after positioning of the occluder device.

Comunicación interauricular (para Niños)

J Am Soc Echocardiogr ; Hoffman JI, Christianson R. While maintaining firm but not undue pressure on the septum and under continuous TEE guidance, the balloon is slowly defated until it pops through the defect into the right atrium.

Mitral valve leafets might be encroached by the occluder device, producing mitral regurgitation in a defect with a defcient AV rim and, infow from the SVC and RUPV might be compromised in a defect with a defcient SVC rim. Under TEE guidance, the occluder device is scanned in 2-D and with CD in several views, looking for proper positioning and residual shunts.

  CONEXION DE MOTORES TRIFASICOS PDF

Left ventricular conditioning in the elderly patient to prevent congestive heart failure after transcatheter closure of atrial septal defect. Given the fragility of the left atrial appendage, it is essential to avoid entering this thin-walled structure with catheters or the stiff guidewire, because this could cause perforation and lead to pericardial effusion.

Percutaneous closure of significant shunting associated with secundum ASD represents an attractive less-invasive alternative therapy to surgery and is being increasingly performed worldwide. It intfrauricular not uncommon to have discrete residual integauricular or peri-prosthetic shunts, which usually will disappear after endothelialization of the occluder device Figure Absent posteroinferior and anterosuperior atrial septal defect rims: Abstract The purpose of this paper is to review the usefulness of multiplanar transesophageal echocardiography before, during and after percutaneous transcatheter closure of secundum atrial septal defects.

Quantitative analysis of the morphology of secundum-type atrial septal defects and their dynamic change using transesophageal three-dimensional echocardiography.

The purpose of this paper is to review the usefulness of multiplanar transesophageal echocardiography before, during and after percutaneous transcatheter closure of secundum atrial septal defects. The amount of contrast needed to infate the balloon to this diameter is carefully recorded and the balloon is then completely defated and withdrawn from the patient.

It is important to be aware of the potential long term complications such as encroachment of mitral or aortic valve leafets, impairment of fow from the pulmonary veins, reactive or hemorrhagic pericarditis, and migration or dislodgement of the device. Long-term follow up should be performed with TTE at three, six and 12 months after the procedure and when clinically indicated thereafter. For reasons of clarity, anatomic connotations are used herein.

Device preparation for delivery is an important process of PTC and requires a meticulous approach on behalf of the interventional cardiologist Figure Echocardiologists’ role in the deployment of the Amplatzer atrial septal occluder device in adults. J Am Coll Cardiol ;6: The defect must have a favorable anatomy, with adequate rims of at least 5 mm to anchor the prosthesis.

To simplify this classification we refer to Table 1. Abnormal septal motion of the inter-ventricular septum is expected to normalize shortly after ee procedure.

Transesophageal echocardiography plays a critical role before the procedure in identifying potential candidates for percutaneous closure and to exclude those with unfavorable anatomy or associated lesions, which could not be addressed percutaneously. The size of the ASD changes during the cardiac cycle; the maximal ASD diameter must be measured at the end of ventricular systole.

  MANIHOT GLAZIOVII PDF

There was a problem providing the content you requested

It is important to recognize that only when the largest diameter is strictly craneo-caudal in direction, will it truly estimate the full size of the defect, achieving a figure “8” pattern view.

The evaluation of the IVC rim is fundamental Figure 8Bbecause PTC would be very challenging in its absence, 14 it is, however, usually cominicacion most diffcult to visualize and measure, and retrofexion of the probe may help when it is not visible in the standard bi-caval view.

When resistance of the septum is encountered and TEE confirms good apposition of the LA disk with the rims of the ASD, the right atrial comuniczcion of coerre prosthesis is opened inside the RA, allowing the prosthesis to grasp the rims of the ASD between its two disks Figure TEE is the ideal imaging and assessment tool to evaluate and guide procedures and determine immediate procedural success, while ruling out complications.

Transvenous closure of moderate and large secundum atrial septal defects in adults using the Amplatzer septal occluder. TEE during device positioning, deployment, and release. Multiplanar transesophageal echocardiography for the evaluation and percutaneous management of ostium secundum atrial septal defects in the adult. Transesophageal echocardiography imaging techniques, including their role in patient selection, procedural guidance and immediate assessment of technical success and complications comnuicacion described and discussed in this review.

Am J Cardiol ; TEE interauricylar of ASD includes evaluation of the number and localization of the defect sdimensions and adequacy of the rims, direction and severity of the shunt, and the presence of possible associated defects. Thereafter the device is pulled toward the RA, so that its superior portion catches the superior aspect of the ASD Figure